hahahaly(hahahaly)
Mechanical plumbing vent went bad-smell from under a sink-repaired
Found a bad mechanical vent under my kitchen sink. I knew it was bad because of the foul sewer gas smell. The official term is 'air admittance valve'.Instal...
(#14539101@0)
Last Updated: 2022-5-3
This post has been archived. It cannot be replied.
Replies, comments and Discussions:
-
枫下家园 / 美丽家居 / 谢谢! 请问这是怎么回事? 下水道堵了。割天花板,钜管子,通条通,化学剂,热水冲。顺畅了,按原样接回。忙了一星期。可是,一用水就出臭气,这是怎么回事?
-asrsparis(丝丝响);
2022-5-3
(#14539030@0)
-
下水道防臭气的U型管没了?我瞎猜的
-vicky2005(孩子她爹);
2022-5-3
(#14539047@0)
+1
-
计算机专业有一术语high water mark HWM
-**🌱;
2022-5-3
(#14539055@0)
-
水封没了,可能是sink下的p管拆了,
-googlebot(bot);
2022-5-3
(#14539064@0)
-
请看图,原来也这样,我按原样接回去,现在用水时,那个管子出臭气。请问怎么fix。谢谢!
-asrsparis(丝丝响);
2022-5-3
{233}
(#14539088@0)
:
-
那个管子是 air vent 坏了
-hahahaly(hahahaly);
2022-5-3
{563}
(#14539101@0)
Mechanical plumbing vent went bad-smell from under a sink-repaired
Found a bad mechanical vent under my kitchen sink. I knew it was bad because of the foul sewer gas smell. The official term is 'air admittance valve'.Instal...
-
我拆的时候就是一根普通的管子,没有air vent按在上面
-asrsparis(丝丝响);
2022-5-3
(#14539111@0)
-
可能以前那里也堵了(安装忘了, 以后人为堵上了,下水慢些但比臭烘烘强), 现在你一通整, 整个都通畅了, 如没有那个装置, 一定会有臭气
-hahahaly(hahahaly);
2022-5-3
(#14539121@0)
-
谢谢! 这更管子很长,没有空间放vent上去,必须拆了,或钜断,按vent后接回去,那就会短一点。请问,这根管子的长度有讲究吗? 谢谢!
-asrsparis(丝丝响);
2022-5-3
(#14539164@0)
-
这个管子就是vent, 上面要安装一个小的通气盖子(不大- 你看YouTube最后那个人用嘴吹的部分),长度 - 不太懂。
-hahahaly(hahahaly);
2022-5-3
(#14539172@0)
-
感谢! 这个下水道横穿房子到另一边,如果直接在墙上打个洞外接墙外的雨水管可以吗?
-asrsparis(丝丝响);
2022-5-3
(#14539191@0)
-
现在的house都有这个air vent吗?一直没发现这个小零件
-imvisitor(小李飞刀);
2022-5-3
(#14539209@0)
-
水喉是必须的。air vent用在没办法按水喉的地方的替代方法,实属权宜之计,例如水池设在了中央岛上。
-2841999(四友);
2022-5-3
(#14539386@0)
-
多谢解释!
-imvisitor(小李飞刀);
2022-5-4
(#14542729@0)
-
水池下有两根垂直的管子,一根是水池下的金属管,一根是并列的黑管。它俩上部连在一起没有(在铜管的部位)?
-2841999(四友);
2022-5-3
(#14539318@0)
-
谢谢 -hahahaly和大家! 装上盖子后,问题解决
-asrsparis(丝丝响);
2022-5-4
(#14541095@0)
+1